1.Identification 1.1 GHS Product identifier Product name | 2-hydroxyethyl methacrylate |
1.2 Other means of identification Product number | - |
Other names | 2-Hydroxyethyl methacrylate |
1.3 Recommended use of the chemical and restrictions on use Identified uses | For industry use only.Adhesives and sealant chemicals,Intermediates,Paint additives and coating additives not described by other categories,Photosensitive chemicals |
Uses advised against | no data available |
1.4 Supplier's details Company | MOLBASE (Shanghai) Biotechnology Co., Ltd. |
Address | Floor 4 & 5, Building 12, No. 1001 North Qinzhou Road, Xuhui District, Shanghai, China |
Telephone | +86(21)64956998 |
Fax | +86(21)54365166 |
1.5 Emergency phone number Emergency phone number | +86-400-6021-666 |
Service hours | Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours). |
2. Hazard identification 2.1 Classification of the substance or mixture Skin irritation, Category 2
Eye irritation, Category 2
Skin sensitization, Category 1
2.2 GHS label elements, including precautionary statements Pictogram(s) | |
Signal word | Warning |
Hazard statement(s) | H315 Causes skin irritation H319 Causes serious eye irritation H317 May cause an allergic skin reaction |
Precautionary statement(s) | |
Prevention | P264 Wash ... thoroughly after handling. P280 Wear protective gloves/protective clothing/eye protection/face protection. P261 Avoid breathing dust/fume/gas/mist/vapours/spray. P272 Contaminated work clothing should not be allowed out of the workplace. |
Response | P302+P352 IF ON SKIN: Wash with plenty of water/... P321 Specific treatment (see ... on this label). P332+P313 If skin irritation occurs: Get medical advice/attention. P362+P364 Take off contaminated clothing and wash it before reuse. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337+P313 If eye irritation persists: Get medical advice/attention. P333+P313 If skin irritation or rash occurs: Get medical advice/attention. |
Storage | none |
Disposal | P501 Dispose of contents/container to ... |
2.3 Other hazards which do not result in classification 3.Composition/information on ingredients 3.1 Substances Chemical name | Common names and synonyms | CAS number | EC number | Concentration |
2-hydroxyethyl methacrylate | 2-hydroxyethyl methacrylate | 868-77-9 | none | 100% |
4.First-aid measures 4.1 Description of necessary first-aid measures General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
Fresh air, rest. Refer for medical attention.
Following skin contact
First rinse with plenty of water for at least 15 minutes, then remove contaminated clothes and rinse again. Refer for medical attention .
Following eye contact
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Following ingestion
Rinse mouth. Do NOT induce vomiting. Give one or two glasses of water to drink. Refer immediately for medical attention.
4.2 Most important symptoms/effects, acute and delayed 4.3 Indication of immediate medical attention and special treatment needed, if necessary Basic treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary ... . Monitor for shock and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with normal saline during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 mL/kg up to 200 mL of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool. Administer activated charcoal ... . /Esters and related compounds/
5.Fire-fighting measures 5.1 Extinguishing mediaSuitable extinguishing media
Use water spray, dry powder, alcohol-resistant foam.
5.2 Specific hazards arising from the chemical 5.3 Special protective actions for fire-fighters Wear self-contained breathing apparatus for firefighting if necessary.
6.Accidental release measures 6.1 Personal precautions, protective equipment and emergency procedures Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.
6.2 Environmental precautions Personal protection: chemical protection suit and filter respirator for organic gases and vapours adapted to the airborne concentration of the substance. Collect leaking liquid in covered containers. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
6.3 Methods and materials for containment and cleaning up Pick up and arrange disposal. Sweep up and shovel. Keep in suitable, closed containers for disposal.
7.Handling and storage 7.1 Precautions for safe handlingAvoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.
7.2 Conditions for safe storage, including any incompatibilities Store only if stabilized. Keep in the dark. Cool. Ventilation along the floor.Temp during storage must be kept low to minimize formation of peroxides and other oxidation products. ... Storage temp below 30°C are recommended for the polyfunctional methacrylates. ... The methacrylate monomers should not be stored for longer than one year. Shorter storage times are recommended for the aminomethacrylates, ie, three months, and the polyfunctional methacrylates, ie, six months. Many of these cmpd are sensitive to UV light and should, therefore, be stored in the dark. The methacrylic esters may be stored in mild steel, stainless steel, or aluminum. /Methacrylic acid & derivatives/
8.Exposure controls/personal protection 8.1 Control parametersOccupational Exposure limit values
8.2 Appropriate engineering controls Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
8.3 Individual protection measures, such as personal protective equipment (PPE)Eye/face protection
Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Respiratory protection
Wear dust mask when handling large quantities.
Thermal hazards
no data available
9.Physical and chemical properties Physical state | colourless liquid |
Colour | Clear mobile liquid |
Odour | no data available |
Melting point/ freezing point | 183°C(lit.) |
Boiling point or initial boiling point and boiling range | 85°C/5mmHg(lit.) |
Flammability | Combustible. |
Lower and upper explosion limit / flammability limit | no data available |
Flash point | 107°C(lit.) |
Auto-ignition temperature | no data available |
Decomposition temperature | no data available |
pH | no data available |
Kinematic viscosity | 8.4 mm²/s at 20°C |
Solubility | In water: soluble |
Partition coefficient n-octanol/water | log Kow= 0.47 |
Vapour pressure | 0.01 mm Hg ( 25 °C) |
Density and/or relative density | 1.073 |
Relative vapour density | 5 (vs air) |
Particle characteristics | no data available |
10.Stability and reactivity 10.1 Reactivity 10.2 Chemical stability AN INHIBITOR IS USUALLY ADDED TO SOLUTIONS TO PROLONG SHELF LIFE.
10.3 Possibility of hazardous reactions 30% GRADE (WITH XYLENE) IS FLAMMABLE; MODERATE FIRE RISK.
10.4 Conditions to avoidno data available
10.5 Incompatible materials no data available
10.6 Hazardous decomposition products When heated to decomp it emits acrid smoke and irritating fumes.
11.Toxicological information Acute toxicity
- Oral: LD50 Rat oral 11.2 g/kg
- Inhalation: no data available
- Dermal: LD50 Rabbit percutaneous > 3.0 g/kg
Skin corrosion/irritation
no data available
Serious eye damage/irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
no data available
Reproductive toxicity
no data available
STOT-single exposure
no data available
STOT-repeated exposure
no data available
Aspiration hazard
no data available
12.Ecological information 12.1 Toxicity - Toxicity to fish: LC50 Pimephales promelas (fathead minnows) 0.99 g/l/96 hr (95% confidence limit 0.90-1.1 g/l); age 30 days old, water hardness 45.6 mg/l calcium carbonate, temp 24.9°C, pH 7.66, dissolved oxygen 7.1 mg/l, alkalinity 44.4 mg/l (CaCO3), Tank vol: 2.0 l, additions: 18 vol/day (flow-through bioassay)
- Toxicity to daphnia and other aquatic invertebrates: no data available
- Toxicity to algae: no data available
- Toxicity to microorganisms: no data available
12.2 Persistence and degradability2-Hydroxyethyl methacrylate, present at 100 mg/l, reached 92-100% of its theoretical BOD in 2 weeks using an activated sludge inoculum and the Japanese MITI test(1).
12.3 Bioaccumulative potentialAn estimated BCF of 1.3 was calculated for 2-hydroxyethyl methacrylate(SRC), using a log Kow of 0.47(1). According to a classification scheme(2), this BCF suggests the potential for bioconcentration in aquatic organisms is low.
12.4 Mobility in soilThe Koc of 2-hydroxyethyl methacrylate is estimated as approximately 43(SRC), using a log Kow of 0.47(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that 2-hydroxyethyl methacrylate is expected to have very high mobility in soil.
12.5 Other adverse effects no data available
13.Disposal considerations 13.1 Disposal methods Product
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Contaminated packaging
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
14.Transport information 14.1 UN Number ADR/RID: Not dangerous goods. | IMDG: Not dangerous goods. | IATA: Not dangerous goods. |
14.2 UN Proper Shipping Name ADR/RID: Not dangerous goods. |
IMDG: Not dangerous goods. |
IATA: Not dangerous goods. |
14.3 Transport hazard class(es) ADR/RID: Not dangerous goods. | IMDG: Not dangerous goods. | IATA: Not dangerous goods. |
14.4 Packing group, if applicable ADR/RID: Not dangerous goods. | IMDG: Not dangerous goods. | IATA: Not dangerous goods. |
14.5 Environmental hazards ADR/RID: no | IMDG: no | IATA: no |
14.6 Special precautions for user no data available
14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code no data available
15.Regulatory information 15.1 Safety, health and environmental regulations specific for the product in question Chemical name | Common names and synonyms | CAS number | EC number |
2-hydroxyethyl methacrylate | 2-hydroxyethyl methacrylate | 868-77-9 | none |
European Inventory of Existing Commercial Chemical Substances (EINECS) | Listed. |
EC Inventory | Listed. |
United States Toxic Substances Control Act (TSCA) Inventory | Listed. |
China Catalog of Hazardous chemicals 2015 | Not Listed. |
New Zealand Inventory of Chemicals (NZIoC) | Listed. |
Philippines Inventory of Chemicals and Chemical Substances (PICCS) | Listed. |
Vietnam National Chemical Inventory | Listed. |
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) | Listed. |
16.Other information Information on revision
Creation Date | Nov 28, 2017 |
Revision Date | Nov 28, 2017 |
Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
References
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/
Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.