Product name | Iodine monochloride |
---|
Product number | - |
---|---|
Other names | IODINE MONOCHLORIDE |
Identified uses | For industry use only. |
---|---|
Uses advised against | no data available |
Company | MOLBASE (Shanghai) Biotechnology Co., Ltd. |
---|---|
Address | Floor 4 & 5, Building 12, No. 1001 North Qinzhou Road, Xuhui District, Shanghai, China |
Telephone | +86(21)64956998 |
Fax | +86(21)54365166 |
Emergency phone number | +86-400-6021-666 |
---|---|
Service hours | Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours). |
Acute toxicity - Oral, Category 2
Acute toxicity - Dermal, Category 3
Skin corrosion, Category 1A
Specific target organ toxicity – single exposure, Category 3
2.2 GHS label elements, including precautionary statementsPictogram(s) | ![]() ![]() |
---|---|
Signal word | Danger |
Hazard statement(s) | H300 Fatal if swallowed H311 Toxic in contact with skin H314 Causes severe skin burns and eye damage H335 May cause respiratory irritation |
Precautionary statement(s) | |
Prevention | P264 Wash ... thoroughly after handling. P270 Do not eat, drink or smoke when using this product. P280 Wear protective gloves/protective clothing/eye protection/face protection. P260 Do not breathe dust/fume/gas/mist/vapours/spray. P261 Avoid breathing dust/fume/gas/mist/vapours/spray. P271 Use only outdoors or in a well-ventilated area. |
Response | P301+P310 IF SWALLOWED: Immediately call a POISON CENTER/doctor/… P321 Specific treatment (see ... on this label). P330 Rinse mouth. P302+P352 IF ON SKIN: Wash with plenty of water/... P312 Call a POISON CENTER/doctor/…if you feel unwell. P361+P364 Take off immediately all contaminated clothing and wash it before reuse. P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower]. P363 Wash contaminated clothing before reuse. P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P310 Immediately call a POISON CENTER/doctor/… P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. |
Storage | P405 Store locked up. P403+P233 Store in a well-ventilated place. Keep container tightly closed. |
Disposal | P501 Dispose of contents/container to ... |
none
3.Composition/information on ingredients 3.1 SubstancesChemical name | Common names and synonyms | CAS number | EC number | Concentration |
---|---|---|---|---|
Iodine monochloride | Iodine monochloride | 7790-99-0 | none | 100% |
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaledIf breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contactWash off with soap and plenty of water. Consult a physician.
In case of eye contactRinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowedNever give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
4.2 Most important symptoms/effects, acute and delayedExcerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]: TOXIC; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death. Reaction with water or moist air may release toxic, corrosive or flammable gases. Reaction with water may generate much heat that will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2016)
4.3 Indication of immediate medical attention and special treatment needed, if necessary Minimum/Potential Fatal Human Dose3 (?). 3= MODERATELY TOXIC: PROBABLE ORAL LETHAL DOSE (HUMAN) BETWEEN 1 OUNCE & 1 PINT (OR 1 LB) FOR 70 KG PERSON (150 LB). /IODIDE SALTS/
Absorption, Distribution and ExcretionIODINE MONOCHLORIDE HAS ABILITY TO PENETRATE BACTERIAL CELL & ACCUM IN CELL WALL & PROTOPLASTS.
5.Fire-fighting measures 5.1 Extinguishing media Suitable extinguishing mediaExcerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]: Note: Some foams will react with the material and release corrosive/toxic gases. SMALL FIRE: CO2 (except for Cyanides), dry chemical, dry sand, alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam. Move containers from fire area if you can do it without risk. Use water spray or fog; do not use straight streams. Dike fire-control water for later disposal; do not scatter the material. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2016)
5.2 Specific hazards arising from the chemicalExcerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]: Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. For UN1796, UN1826, UN2031 at high concentrations and for UN2032, these may act as oxidizers, also consult ERG Guide 140. Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars, etc.). Substance may react with water (some violently), releasing corrosive and/or toxic gases and runoff. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated or if contaminated with water. (ERG, 2016)
5.3 Special protective actions for fire-fightersWear self-contained breathing apparatus for firefighting if necessary.
6.Accidental release measures 6.1 Personal precautions, protective equipment and emergency proceduresUse personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.
6.2 Environmental precautionsPrevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.
6.3 Methods and materials for containment and cleaning upPick up and arrange disposal. Sweep up and shovel. Keep in suitable, closed containers for disposal.
7.Handling and storage 7.1 Precautions for safe handlingAvoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.
7.2 Conditions for safe storage, including any incompatibilitiesMAY BE STORED IN BROWN GLASS-STOPPERED BOTTLES.
8.Exposure controls/personal protection 8.1 Control parameters Occupational Exposure limit valuesno data available
Biological limit valuesno data available
8.2 Appropriate engineering controlsHandle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
8.3 Individual protection measures, such as personal protective equipment (PPE) Eye/face protectionSafety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protectionWear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Respiratory protectionWear dust mask when handling large quantities.
Thermal hazardsno data available
9.Physical and chemical propertiesPhysical state | red to brown liquid |
---|---|
Colour | BLACK CRYSTALS OR REDDISH-BROWN LIQ |
Odour | no data available |
Melting point/ freezing point | 26-98ºC |
Boiling point or initial boiling point and boiling range | 97.4°C(lit.) |
Flammability | no data available |
Lower and upper explosion limit / flammability limit | no data available |
Flash point | 96-98°C |
Auto-ignition temperature | no data available |
Decomposition temperature | no data available |
pH | no data available |
Kinematic viscosity | no data available |
Solubility | In water:decomposes |
Partition coefficient n-octanol/water (log value) | no data available |
Vapour pressure | no data available |
Density and/or relative density | 3.24g/mLat 25°C(lit.) |
Relative vapour density | no data available |
Particle characteristics | no data available |
no data available
10.2 Chemical stabilityStable under recommended storage conditions.
10.3 Possibility of hazardous reactionsALUMINUM FOIL, AFTER CONTINUED CONTACT WITH IODINE MONOCHLORIDE, IGNITES SPONTANEOUSLY & BURNS WITH BLUISH-WHITE FLAME.IODINE MONOCHLORIDE is moderately explosive when heated [Lewis]. Reacts with rubber and many organic materials. Enflames (after a period of delay) with aluminum foil [Mellor 2:119(1946-1947)]. Reacts dangerously with other active metals. Reacts vigorously with cadmium sulfide, lead sulfide, silver sulfide, and zinc sulfide [Mellor 2, Supp. 1:502(1956)]. Combines very exothermically with phosphorus trichloride [Mellor 2, Supp. 1:502(1956)]. Forms Iodine pentaoxide in air which reacts explosively when warmed with carbon, sulfur, sugar, resin, or powdered combustible elements [Mellor 8: 841(1946-1947)].
10.4 Conditions to avoidno data available
10.5 Incompatible materialsIODINE MONOCHLORIDE PRODUCES VIGOROUS REACTION WITH CORK, RUBBER, & OTHER ORGANIC SUBSTANCES. PHOSPHORUS REACTS VIOLENTLY WITH MOLTEN...IODINE MONOCHLORIDE. REACTION.../WITH/ PHOSPHORUS TRICHLORIDE IS INTENSELY EXOTHERMAL. ...REACTION OF SODIUM IS VERY SLOW.
10.6 Hazardous decomposition productsWhen heated to decomposition, it emits highly toxic fumes of /hydrogen chloride and hydrogen iodide/ and may explode.
11.Toxicological information Acute toxicity- Oral: no data available
- Inhalation: no data available
- Dermal: no data available
no data available
Serious eye damage/irritationno data available
Respiratory or skin sensitizationno data available
Germ cell mutagenicityno data available
Carcinogenicityno data available
Reproductive toxicityno data available
STOT-single exposureno data available
STOT-repeated exposureno data available
Aspiration hazardno data available
12.Ecological information 12.1 Toxicity- Toxicity to fish: no data available
- Toxicity to daphnia and other aquatic invertebrates: no data available
- Toxicity to algae: no data available
- Toxicity to microorganisms: no data available
no data available
12.3 Bioaccumulative potentialno data available
12.4 Mobility in soilno data available
12.5 Other adverse effectsno data available
13.Disposal considerations 13.1 Disposal methods ProductThe material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Contaminated packagingContainers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
14.Transport information 14.1 UN NumberADR/RID: UN1792 | IMDG: UN1792 | IATA: UN1792 |
ADR/RID: IODINE MONOCHLORIDE, SOLID |
IMDG: IODINE MONOCHLORIDE, SOLID |
IATA: IODINE MONOCHLORIDE, SOLID |
ADR/RID: 8 | IMDG: 8 | IATA: 8 |
ADR/RID: II | IMDG: II | IATA: II |
ADR/RID: no | IMDG: no | IATA: no |
no data available
14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Codeno data available
15.Regulatory information 15.1 Safety, health and environmental regulations specific for the product in questionChemical name | Common names and synonyms | CAS number | EC number |
---|---|---|---|
Iodine monochloride | Iodine monochloride | 7790-99-0 | none |
European Inventory of Existing Commercial Chemical Substances (EINECS) | Listed. | ||
EC Inventory | Listed. | ||
United States Toxic Substances Control Act (TSCA) Inventory | Listed. | ||
China Catalog of Hazardous chemicals 2015 | Listed. | ||
New Zealand Inventory of Chemicals (NZIoC) | Listed. | ||
Philippines Inventory of Chemicals and Chemical Substances (PICCS) | Listed. | ||
Vietnam National Chemical Inventory | Not Listed. | ||
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) | Listed. |
Creation Date | Aug 17, 2017 |
---|---|
Revision Date | Aug 17, 2017 |
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/